Semiconductor production: the shields are in a cleanroom according to ISO Class 3 installed: ISO Class 3: for example, max 35 particles in the size of 0.5µm (0.5 micro-meters) per m3 are accepted.

Clean room classes in accordance with ISO 14644-1

  Particle per m²
Class 0.1 µm 0.2 µm 0.3 µm 0.5 µm 1.0 µm 5.0 µm
ISO 1  10 2        
ISO 2 100  24 10 4    
ISO 3  1.000  237  102  35 8  
ISO 4  10.000  2.370  1.020  352  83  
ISO 5  100.000  23.700  10.200  3.530  832  29
ISO 6  1.000.000  237.000  102.000  35.200  8.320  293
ISO 7        352.000  83.200  2.930
ISO 8        3.520.000  832.000  29.300
ISO 9       35.200.000  8.320.000  293.000

Pictures

SL370171

.

 

IMG 3060

. SL370191
Mounting the shield
 
Measurement of the shielding effect
  Company logo

ETH Lausanne, Surface shielding laboratory ::

Pictures

IMG 2988 . IMG 2989 . IMG 2995
The laboratory room during the shielding work:
floor, ceiling, walls are being shielded
 
Assembly of the wall shielding
 
Wall shield firmly screwed before welding the impact junction
         
IMG 3001   IMG 2989  
ETH Lausanne
Picture 4
 
Picture 5
 
 FEI TEM installation "Video"

SBB Main Station Zurich, Surface shielding ::

Space shielding to comply with the AGW
 
In the largest train station in Switzerland, the main station in Zurich, the transformer station 24 had to be moved locally because of the construction of the new diameter line. Directly above and below the transformer station are places of sensitive use "OMEN", namely the shops of the Shopville below the transformer station and the Kiosk systems above the transfer station. In accordance with the regulation of non-ionising radiation, NISV, the installation limit value, AGW, has to be adhered to. To do so, the entire transformer station opposite the OMEN has to be shielded upwards and downwards. The transformer station consists of three separate rooms, one room for the four transformers, one for the medium-voltage switchgear and one for the low voltage distribution. The rooms were passively shielded with Systron Power Shield® on all sides, floor, ceiling and walls. The shielded area is approximately 800m2.
NSV-Raum-letzte-Schweissnaht . NSV-Raum-mit-Rost . MS-Raum-mit-MS
The low voltage room during the shielding work: floor, ceiling, walls are shielded.
 
The low voltage room completely shielded. The framework for the distribution is already set.
  The medium voltage room completely shielded with integrated medium voltage system.

Binnig and Rohrer Nano Technology Center, "Low Field Room™"::

"Low Field Room™" for nano-tech laboratories 

Description and concept

In the Binnig and Rohner NanoTechnology Center, Rueschlikon, Zurich, so-called "Noise free" rooms, laboratories for extremely sensitive measurements and experiments, were implemented. These laboratories were also protected against the influence of low-frequency magnetic fields. The Specification: "Magnetic Fields rail 16.7 Hz and in-house 50 Hz fields (and harmonics) are to be limited to values of <5nT (internal specification for low-noise optimized laboratories, Noise Free Labs)". Named as the in-house main sources of interference were the transformer station with NS-distribution and MS-system, the air-conditioning control panel and cable channels. In addition, the DC-fields of the lift and the fields of the trucks driving in and out of the delivery had to be included in the concept.
 
The guaranteed compliance of the specified values has been assured with the  "Low Field Room™" concept of Systron EMV GmbH, which was specially developed for those laboratories, it is a combination of magnetic field shielding and compensation system. The shielding fulfills the function of a "basic" field reduction, the compensation limits the remaining fields to the required values. Special about this system is, the shield and the compensation system are coordinated so that there are no interactions between the systems.

Passive shielding and active compensation

Passive shielding: 

The soft annealed nickel-iron (so-called "Mu-metals") and aluminum consisting passive shield was installed on the floor, walls and ceiling in all laboratories. In addition to the laboratory space shields, the walls and ceiling of the in-house transformer station and climate control center were shielded in the same way. The passive shielding of the Laboratories reduces external noise fields on the one hand and on the other prevents fields from entering the neighboring laboratories. The passive shielding homogenized the fields, therefore a large-volume compensation is possible.

Active compensation:

After the fields are already greatly reduced with the passive space shields, the remaining fields are reduced to <5nT with the compensation (32dB). Via a sensor (placed as close as possible to the "Tools") the remaining fields are measured and compensated through six coil pairs by counter fields. The compensation system operates in the frequency range between 0.00 1Hz (DC) and 10kHz. Therefore, both DC- (elevator, trucks, doors) and AC-fields (path and power) are compensated.

Pictures

IBM Binnig und Rohner Nanotechcenter, Neubau Grundriss IBM Noise Free Labs Noise Free Lab im Rohbau Magnetfeldmessung im Noise Free Lab
In Construction: Binnig and Rohner Nano Technology Center
The layout of the "Noise Free Labs"
"Noise Free Lab" shell construction, room height 6.4m
Review of the measured values during the shielding installation
Raum geschirmt mit Innenwand IBM Noise Free Labs Lüftungsdurchführungen IBM Noise Free Labs abgeschirmte Mediendurchführungen IBM Noise Free Lab abgeschirmt mit Powershield
"Noise Free Lab" preliminary construction Shielded ventilation openings Shielded media penetrations "Noise Free Lab" fully developed

Measurement Results

Shielding effect of passive shielding regarding near fields:
Magnetfeldmessung Spule
Magnetfeldmessung Noise Free Lab
Reduction factor passive shielding: 30-50
 
With this measurement, the shielding effect of the passive shielding, regarding sources of interference in the vicinity, has been reviewed. 50Hz magnetic fields were generated with a coil placed outside the laboratory and the values were measured within and in the same distance outside the laboratory. 

 
Measurement structure Measurement results

Shielding effect of passive shielding regarding fields with single conductor characteristics:
Situation Magnetfeldmessung Magnetfeldmessung Noise Free Lab
Reduction factor passive shielding: 20-30

With this measurement, the shielding effect of passive shielding, regarding sources of interference with single conductor characteristics (compensating currents) has been reviewed. 50Hz magnetic fields were generated with a single conductor placed outside the laboratory and the values were measured within and in the same distance outside the laboratory.
Measurement structure Measurement results  

Field reduction of the active compensation:
dc felder ohne kompensation dc felder mit kompensation
Reduction factor active compensation

With this measurement the effect of the active compensation has been reviewed. Used as source was the elevator, which can still have a disturbing effect at a distance of 15m. This is the reason why the goods lift is blocked during sensitive measurements. DC interference fields of vehicles are actively limited with the compensation system.
 
DC fields without compensatio
 DC fields with compensation

Systron EMV GmbH was founded in 1993 by Robert Hauri and Rudolf Käppeli and is specialised in planning, production, distribution and installation of passive magnetic shielding, active magnetic field compensation systems and software simulations.

Many products and shielding systems were developed by Systron itself or in cooperation with partners. From the collaboration with Elekztrizitätswerk Zürich for example, resulted the successful shielding system "Systron PowerShield®"*, a shielding system for surfaces, spaces and components.

The activities of Systron EMV GmbH include the production, distribution and installation of systems for the reduction of low frequency magnetic fields such as caused by transformer stations, electric cables, railway lines, power lines, NMR 's but also by electronic devices or magnets. The product range includes not only the passive mumetal shielding systems but also active compensation systems for ebeam applications such as electron microscopes or lithography writers. Additionally, simulations of electrical equipment such as transformer stations, electrical systems, train stations and high voltage cables are carried out for the visualization of the magnetic fields.

Systron EMV GmbH , Switzerland, is based in Dürnten, Zurich Oberland and works closely together with Systron EMV GmbH, Schwabach, Germany. However, despite sharing the same name, the companies are legally independent companies.

*Systron Powershield® is a registered trademark of Systron EMV GmbH, Switzerland

Verantwortlich für den Seiteninhalt

Systron EMV GmbH
Bubikonerstrasse 45a
CH-8635 Dürnten ZH

T +41 (0)55 250 53 20
E-Mail: This email address is being protected from spambots. You need JavaScript enabled to view it.


 

Joomla-Programmierung (HTML, CSS), Webdesign

Systron EMV GmbH
Bubikonerstrasse 45a
CH-8635 Dürnten ZH

T +41 (0)55 250 53 20
E-Mail: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

1. Inhalt des Onlineangebotes

Der Autor übernimmt keinerlei Gewähr für die Aktualität, Korrektheit, Vollständigkeit oder Qualität der bereitgestellten Informationen. Haftungsansprüche gegen den Autor, welche sich auf Schäden materieller oder ideeller Art beziehen, die durch die Nutzung oder Nichtnutzung der dargebotenen Informationen bzw. durch die Nutzung fehlerhafter und unvollständiger Informationen verursacht wurden, sind grundsätzlich ausgeschlossen, sofern seitens des Autors kein nachweislich vorsätzliches oder grob fahrlässiges Verschulden vorliegt.

Alle Angebote sind freibleibend und unverbindlich. Der Autor behält es sich ausdrücklich vor, Teile der Seiten oder das gesamte Angebot ohne gesonderte Ankündigung zu verändern, zu ergänzen, zu löschen oder die Veröffentlichung zeitweise oder endgültig einzustellen.

2. Verweise und Links

Bei direkten oder indirekten Verweisen auf fremde Webseiten ("Hyperlinks"), die außerhalb des Verantwortungsbereiches des Autors liegen, würde eine Haftungsverpflichtung ausschließlich in dem Fall in Kraft treten, in dem der Autor von den Inhalten Kenntnis hat und es ihm technisch möglich und zumutbar wäre, die Nutzung im Falle rechtswidriger Inhalte zu verhindern.

Der Autor erklärt hiermit ausdrücklich, dass zum Zeitpunkt der Linksetzung keine illegalen Inhalte auf den zu verlinkenden Seiten erkennbar waren. Auf die aktuelle und zukünftige Gestaltung, die Inhalte oder die Urheberschaft der verlinkten/verknüpften Seiten hat der Autor keinerlei Einfluss. Deshalb distanziert er sich hiermit ausdrücklich von allen Inhalten aller verlinkten /verknüpften Seiten, die nach der Linksetzung verändert wurden. Diese Feststellung gilt für alle innerhalb des eigenen Internetangebotes gesetzten Links und Verweise sowie für Fremdeinträge in vom Autor eingerichteten Gästebüchern, Diskussionsforen, Linkverzeichnissen, Mailinglisten und in allen anderen Formen von Datenbanken, auf deren Inhalt externe Schreibzugriffe möglich sind. Für illegale, fehlerhafte oder unvollständige Inhalte und insbesondere für Schäden, die aus der Nutzung oder Nichtnutzung solcherart dargebotener Informationen entstehen, haftet allein der Anbieter der Seite, auf welche verwiesen wurde, nicht derjenige, der über Links auf die jeweilige Veröffentlichung lediglich verweist.

3. Urheber- und Kennzeichenrecht

Der Autor ist bestrebt, in allen Publikationen die Urheberrechte der verwendeten Bilder, Grafiken, Tondokumente, Videosequenzen und Texte zu beachten, von ihm selbst erstellte Bilder, Grafiken, Tondokumente, Videosequenzen und Texte zu nutzen oder auf lizenzfreie Grafiken, Tondokumente, Videosequenzen und Texte zurückzugreifen.

Alle innerhalb des Internetangebotes genannten und ggf. durch Dritte geschützten Marken- und Warenzeichen unterliegen uneingeschränkt den Bestimmungen des jeweils gültigen Kennzeichenrechts und den Besitzrechten der jeweiligen eingetragenen Eigentümer. Allein aufgrund der bloßen Nennung ist nicht der Schluss zu ziehen, dass Markenzeichen nicht durch Rechte Dritter geschützt sind!

Das Copyright für veröffentlichte, vom Autor selbst erstellte Objekte bleibt allein beim Autor der Seiten. Eine Vervielfältigung oder Verwendung solcher Grafiken, Tondokumente, Videosequenzen und Texte in anderen elektronischen oder gedruckten Publikationen ist ohne ausdrückliche Zustimmung des Autors nicht gestattet.

4. Datenschutz

Sofern innerhalb des Internetangebotes die Möglichkeit zur Eingabe persönlicher oder geschäftlicher Daten (Emailadressen, Namen, Anschriften) besteht, so erfolgt die Preisgabe dieser Daten seitens des Nutzers auf ausdrücklich freiwilliger Basis. Die Inanspruchnahme und Bezahlung aller angebotenen Dienste ist - soweit technisch möglich und zumutbar - auch ohne Angabe solcher Daten bzw. unter Angabe anonymisierter Daten oder eines Pseudonyms gestattet. Die Nutzung der im Rahmen des Impressums oder vergleichbarer Angaben veröffentlichten Kontaktdaten wie Postanschriften, Telefon- und Faxnummern sowie Emailadressen durch Dritte zur Übersendung von nicht ausdrücklich angeforderten Informationen ist nicht gestattet. Rechtliche Schritte gegen die Versender von sogenannten Spam-Mails bei Verstössen gegen dieses Verbot sind ausdrücklich vorbehalten.

5. Google Analytics

„Diese Website benutzt Google Analytics, einen Webanalysedienst der Google Inc. („Google“). Google Analytics verwendet sog. „Cookies“, Textdateien, die auf Ihrem Computer gespeichert werden und die eine Analyse der Benutzung der Website durch Sie ermöglichen. Die durch den Cookie erzeugten Informationen über Ihre Benutzung dieser Website (einschließlich Ihrer IP-Adresse) wird an einen Server von Google in den USA übertragen und dort gespeichert. Google wird diese Informationen benutzen, um Ihre Nutzung der Website auszuwerten, um Reports über die Websiteaktivitäten für die Websitebetreiber zusammenzustellen und um weitere mit der Websitenutzung und der Internetnutzung verbundene Dienstleistungen zu erbringen. Auch wird Google diese Informationen gegebenenfalls an Dritte übertragen, sofern dies gesetzlich vorgeschrieben oder soweit Dritte diese Daten im Auftrag von Google verarbeiten. Google wird in keinem Fall Ihre IP-Adresse mit anderen Daten von Google in Verbindung bringen. Sie können die Installation der Cookies durch eine entsprechende Einstellung Ihrer Browser Software verhindern; wir weisen Sie jedoch darauf hin, dass Sie in diesem Fall gegebenenfalls nicht sämtliche Funktionen dieser Website vollumfänglich nutzen können. Durch die Nutzung dieser Website erklären Sie sich mit der Bearbeitung der über Sie erhobenen Daten durch Google in der zuvor beschriebenen Art und Weise und zu dem zuvor benannten Zweck einverstanden.“

6. Rechtswirksamkeit dieses Haftungsausschlusses

Dieser Haftungsausschluss ist als Teil des Internetangebotes zu betrachten, von dem aus auf diese Seite verwiesen wurde. Sofern Teile oder einzelne Formulierungen dieses Textes der geltenden Rechtslage nicht, nicht mehr oder nicht vollständig entsprechen sollten, bleiben die übrigen Teile des Dokumentes in ihrem Inhalt und ihrer Gültigkeit davon unberührt

Magnetic Shielding – Active cancellation systems – 3D modelling – Measurements

The key competence of Systron is to design, sell and install passive magnetic shieldings and active compensations systems in order to reduce low-frequency magnetic fields. In addition, we perform 3D magnetic field modelling of electrical power stations and perform measurements on site.
Systron offers standardized and custom-made shielding solutions in order to reduce low-frequency magnetic fields. Magnetic shielding is used either to reduce fields at the electromagnetic source, or to protect EMI sensitive tools like electron microscopes or lithography writers.
Depending on the application, different shielding alloys are selected for efficient passive shielding. Typically, a combination of nickel-iron / silicon-iron and aluminium is used to shield alternating magnetic fields. Heat treated mu-metal is applied where DC-fields needs to be reduced. Alternatively, or in addition, active compensations systems are installed in order to further reduce magnetic fields.

Our goal is to realize the best possible solutions in cooperation with the customer and provide an excellent service. Looking forward to a successful partnership!

 

Subcategories

Go to top